VERSION HISTORY OVERVIEWS FULL INSTALL DIRECTIONS: 1) Create a new folder "C:\SETUP". 2) UNZIP the downloaded file to that folder. 3) RUN FWTOOL (C:\SETUP\FWTOOL.EXE). 4) Click FILE | OPEN then select the new HEX file (sgxxx.hex). 5) Click LOCAL UPDATE (this will take 7-15 minutes to download). 6) Exit FWTOOL. 7) From C:\SETUP run SETUP.EXE to install the new WinEVM into the C:\STARGATE folder. UPDATE DIRECTIONS: 1) Close STARGATE WINEVM (Event Manager). 2) UNZIP the downloaded ZIP file to C:\STARGATE folder (overwrite WINEVM.EXE with new version). 3) RUN FWTOOL (C:\STARGATE\FWTOOL.EXE) 4) Click FILE | OPEN then select the new HEX file (sgxxx.hex). 5) Click LOCAL UPDATE (this will take 7-15 minutes to download). 6) Exit FWTOOL. 7) Open STARGATE Winevm (Event Manager). 8) Click UTILITIES | SELF TEST, then click RUN, then YES to run Self Test. When SELF TEST has completed, click OK to exit. 9) Click on the CLOCK icon, click READ, adjust as necessary, click SET, click DONE to exit. 10) Re-download your schedule. SELECT ALL DOWNLOAD OPTIONS AFTER EVERY SELF TEST. 11) Click Define - Telephone and verify all parameters are correct prior to your first download then click OK. 12) If a GE/Caddx security panel is connected, click Define - Security then click OK to re-establish communication. For future updates: www.jdstechnologies.com 3.10.02 WinEVM (29 JAN 2007) - Fixed Define-Lighting Voice Response editing problem (double-click to edit didn't work). 3.10.0 Build 0 WinEVM/FW (28 FEB 2007) IMPORTANT NOTES: Click Define - Telephone and verify all parameters are correct prior to your first download then click OK. For your first download after the Self-Test, it is essential to select ALL download options to properly initialize STARGATE. If a GE/Caddx security panel is connected, click Define - Security then click OK to re-establish communication. VERSION 3.10.0 Build 0 CHANGES/FIXES: - Update for new Daylight Savings Time dates. Note both the 3.10.0 WinEVM and firmware are required - Fixed LCD Keypad download issues. - Fixed occasional Caddx Security locks. 3.09.6 Build 5 WinEVM/FW (29 AUG 2006) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.09.6 Build 5 CHANGES/FIXES: - Fixed LCD Keypad DigitPad functions - Removed AprilAir support VERSION HISTORY OVERVIEW 3.09.6 WinEVM/FW (29 MAY 2006) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.09.6 CHANGES/FIXES: - Added support for LTS78 Touchscreen - Increased CADDX comm reliability - Removed comm port checking for UPB VERSION HISTORY OVERVIEW 3.08.7 WinEVM/FW (30 AUG 2004) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.08.7 CHANGES/FIXES: - Changed the compression rate for recorded messages. This affects both the user recorded messages and voicemail. Only NEW recordings made with this version will use the new compression rate, any previous messages will retain the compression rate it was recorded at. The compression rate was changed to a slightly lower rate to increase the overall recording time and give the ablitity to properly calculate the remaining time. - Corrected the calcuated User Voice Response "Time Remaining" value. It was previously based on an inaccurate compression rate. - Changed the way CADDX partition information is handled. It now uses the "Partition Status" message instead of "Partion Snapshot". This requires the following CADDX change: Consult the CADDX application note for details on how to program the bits and use the following information to change your settings. If you have an NX-8/6/4 w/NX584: Location 2, Segment 1, Bits to turn ON -----67- If you have an NX-8E: Location 210, Segment 1, Bits to turn ON -----67- VERSION HISTORY OVERVIEW 3.08.3 WinEVM/FW (25 FEB 2004) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.08.3 CHANGES/FIXES: - Fixed COM2/COM3 Modem usage - Fixed the erroneous HVAC Timeout reporting in the activity log - Added the IF Condition for CADDX User Number (see NOTE below) - Added the THEN Condition for CADDX User Number to user_VAR NOTE: To use the CADDX User Number feature, the CADDX will need an additional "Enable Transition bit" (number 7) to be turned ON. This bit will enable partition messages that contain the user number to be sent. Each user (or security passcode) is organized by user number in the CADDX system. This number is sent to the StarGate whenever a partition type message is sent (Arm, Disarm, etc) and can be used to determine which user last accessed the security panel. Consult the CADDX application note for details on how to program the bits and use the following information to change your settings. If you have an NX-8/6/4 w/NX584: Location 2, Segment 1, Bits to turn ON -----678 If you have an NX-8E: Location 210, Segment 1, Bits to turn ON -----678 VERSION HISTORY OVERVIEW 3.08.2 WinEVM (21 JAN 2004) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.08.2 CHANGES/FIXES: - Increased COM2/COM3 ASCII-IN response - Added the IF Condition for RS485 ASCII-IN - Fixed Time based conditions with Security mode enabled for times after 11pm. - Fixed Time based conditions that would become false at 2pm. VERSION HISTORY OVERVIEW 3.08.0 WinEVM (11 Dec 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.08.0 CHANGES/FIXES: - Updated FWTool.exe to support PCs with USB-Serial adapters. - Fixed loading the user_VAR with the Heat or Cool setpoint values. - Fixed the schedule shrink problem when used in conjuction with the WebX or any other traffic intensive device on COM1. - Fixed the "reboot then halt" problem by relocating data storage. - Fixed the Statnet KPG8 temperature update problem. VERSION HISTORY OVERVIEW 3.07.3 WinEVM (10 Oct 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.07.3 CHANGES/FIXES: - Recompiled WinEVM to faciliate pre-loading of modules. This change fixes WinEVM crashes when viewing certain dialog boxes. VERSION HISTORY OVERVIEW 3.07 FW Only (1 July 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.07 CHANGES/FIXES: - Added support for the new RCS dual setpoint thermostats TR16/TR40 - Fixed a lockup problem due to tasks competing for same resources - Fixed a TR15/TR36 setpoint problem using version 19 and prior KPG8 versions. - Detecting Ring 1 earlier in ring cycle. - Better CADDX syncronization with schedule - Changed CADDX time update from every minute to once a day - Added RCS Thermostat time update (A=255 TIME=), once a day update VERSION HISTORY OVERVIEW 3.05a FW Only (17 June 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.05a CHANGES/FIXES: - Added detection of voicemail messages with no duration (hangups) and auto deletion of those messages - Changed the record "beep" to a 2000Hz, 300ms tone - Fixed HVAC ZC6 zone support problem introduced in 3.05 - Added VOX threshold adjustment (saved in TAD EEPROM) Default value is 05. To adjust the VOX value use ##%5229xx where the xx range is 01 to 09. The lower the value the more sensitive the VOX threshold. VERSION HISTORY OVERVIEW 3.05 (30 May 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.05 CHANGES/FIXES: - Corrected the Daylight Savings flag problem introduced in 3.04 - Corrected the Then Action KPG8 Goto Menu problem in which the goto Telepad would goto Digipad and vise-versa. VERSION HISTORY OVERVIEW 3.04 (24 Mar 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.04 CHANGES/FIXES: - Fixed an IVR download issue VERSION HISTORY OVERVIEW 3.03 (8 Mar 2003) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.03 CHANGES/FIXES: - Fixed the CID timeout problem. - Fixed the Midnight problem - Increased the performance of the RS485 bus. VERSION HISTORY OVERVIEW 3.02 (20 Aug 2002) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. VERSION 3.02 CHANGES/FIXES: - Out Going messsages were being inadvertantly deleted when issuing the delete command with no voice mail messages in that mailbox. A check is made before a delete command is processed to make sure the mailbox contains messages. - When connecting with a modem to COM2 or COM3, a security panel message was being sent to the modem port sometimes causing problems with a modem connection. - Fixed the support for multiple Enerzone Thermostats - Corrected the Extended Code Set Level values to match the Pre-Set values. - Corrected the problem with Enerzone Thermostats reporting any timeouts as zone 1 timeouts. - When editing an LCD Keypad THEN Action, the keypad selection was not being saved, WinEVM 3.02a corrects this. VERSION HISTORY OVERVIEW 3.01 (20 Jul 2001) Non-released version. VERSION HISTORY OVERVIEW 3.00 (13 Apr 2001) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. If you have Time-Labels defined for use with LCD-96M Keypads, for each keypad address: Click Define|LCD Keypad, select the menu containing the Time-Label access button, double-click the Time-Label menu item to access the edit field and verify the correct Time-Label is highlighted, Click OK and re-download the menu. VERSION 3.00 NEW FEATURES: - Increased the number of HVAC zones from 16 to 32. - Added support for CADDX NX series security panels. - Added support for LED 7 button Keypads. - Added support the 16 8-Channel RS-485 Relay Xpanders. - Enhanced the Network Info tool to include the LED keypad, 8CH Relay Xpander and RCS RS-485 thermostats. VERSION 3.00 CHANGES/FIXES: - Fixed a problem with LCD keypad THEN-Action Un-invert command. The command was sometimes causing the line or another line on the LCD screen to change from text to a bitmap. - Disabled the Remote Access Timeout when the CO line is put on hold or taken offhook via the schedule. - Fixed the problem with received X-10 commands sometimes showing as transmitted. - Fixed the problem with power-restore/first-pass getting executed more than once. - Fixed the problem when trying to disconnect/connect audio paths while a voice mail message or other IVR is being monitored. Note that this command was placed into the same buffer as Touch Tone outputs and voice commands when used in a schedule, it now is executed immediately. Schedules that use this command may have to be modified to account for this change. - Fixed the Voice Mail Commands: Incoming Call Monitor ON/OFF. - Corrected a Power Fail catchup issue: under certain conditions the catchup routine would not function properly. - Corrected the problem with user recorded voice messages being deleted. The problem was trace to attempting to delete voice mail messages when there were none, - Added Megacontroller support for the TX15 (RCS one-way X-10) - Added the Megacontroller Caller ID message (taken out in 2.43) - Fixed the initial Digital Input states when Megacontroller first opens. - Fixed the initial IRXP2 Power Sensor states when the Megacontroller first opens. - Fixed a Variable Action var+var indexing problem. - Added a clear delay routine to clear delays that are active. If a delay within a schedule is active when SG loses power, upon power-up the delay could get into a state where it never expires. The clear delay routine will cause any active delay to expire when the SG gets powered up. - Removed the "check for duplicate" function in the Define | X-10 window. - Corrected the sync problem between the time of day and the time of day that can be announce through the voice response commands. VERSION HISTORY OVERVIEW 2.43x40 (08 Oct 2000) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. - Corrected the Midnight problem. This occurs when the time rolls over from 23:59:59 to 0:00:00 and the date not advancing causing X-10 and IR sequences to become true. This was traced down to the Dallas Semi clock chip used, undocumented issues with reading the clock chip too soon after the 1 Hz interrupt catching the date registers while transitioning. - Increased the response time on Digital Inputs. - Corrected the Power Fail Catchup time calculation. The calculated "powered off" time was not correct causing the Power Fail Catchup to not be executed. Version 2.43 major features include: LCD Keypad support VERSION HISTORY OVERVIEW 2.42d (26 Apr 1999) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. - Corrected the DUART Lockup problem that occurs when mulitiple high speed devices are used simulatiously on STARGATEs COM2 and COM3. The symptoms included no serial data transmittion, a failure of COM2 & COM3 during self test and COM2 & COM3 self test passing after a power cycle. - Corrected the Daylight Savings Time changeover problem. - Corrected the sunrise/sunset calculation for Time Zone 0 during the Daylight Savings Time period of April-Oct. - Eliminated forced carriage return when sending ascii out with "\" at the end of a line to the RS-485 port. VERSION HISTORY OVERVIEW 2.42c (10 Jan 1999) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. - Corrected the spurious X-10 commands sent when using the "X-10 Set State to" command. - Corrected the "Duart Test" hangup during a Self Test. - Corrected the missing "Variable bit0 Set" condition not being displayed properly in the schedule. VERSION HISTORY OVERVIEW 2.42b (22 Dec 1998) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. - RCS RS-20 Temperature Sensor: Added support for the RCS RS-20 Remote Temperature Sensors. The RS-20 is an RS-485 temperature sensor that responds to the same command set as the RS-485 Thermostats. Refer to Application note #3, "Interfacing STARGATE to RCS RS-485 Thermostats" for detailed information. VERSION HISTORY OVERVIEW 2.42a (18 Dec 1998) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. - Corrected the "Duart Test COM2 Fail" message reported during a Self Test. VERSION HISTORY OVERVIEW 2.42 (20 Nov 1998) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. Incorporated numerous additions and changes, including: - Enerzone Statnet Thermostat: Added support for the Enerzone Statnet Serial Thermostat using the Proverter RS-485 to RS-232 adapter. Refer to Application note #2, "Interfacing STARGATE to Enerzone Statnet Communicating Thermostats" for detailed information. - RCS RS-485 Thermostat: Added support for the RCS RS-485 Communicating Thermostats. Refer to Application note #3, "Interfacing STARGATE to RCS RS-485 Thermostats" for detailed information. - HVAC IF Conditions: Added support for testing HVAC Modes and Fan states. - Voice Mail Maximum Record Time: Increased maximum record time from 120 seconds to 240 seconds (2 minutes to 4 minutes) - Caller ID ASCII Out: The 16 character name field is now included with the Caller ID number when used in ASCII Out (10 character number + 16 character name). - Recording User Voice Response: When recording a User Voice Response from the ICM or CO, going ON-HOOK will automatically stop the recording. Previous versions would only stop the recording after the record timeout. - X-10 Preset Level ON/OFF: An X-10 device will be considered in the OFF state when Preset Level of 0% is receieved for that device and the ON state for Preset Levels greater than 0%. Setup 1) Click DEFINE | X10 DEVICE. For each Leviton switch address (Housecode/Unitcode), set the "TYPE" to "Extended". Click OK. 2) Click DEFINE | LIGHTING SCENES... A) Select the appropriate Housecode for the Leviton switches whose scene you are defining. B) Select the Scene Number and enter the desired Name ("Evening", "Party", etc.). C) For each Highlighted X10 Address in the list, click the down arrow in the "PreSet Level" column and select the desired Preset Dim Level (from 0% to 100%) for that scene. Select "Not Used" if you don't want the highlighted device included in the scene. Then click "Load Scene" to send the data to the corresponding switches. To test the scene, click the "TEST" button. D) To create another scene for the same group (Housecode) of switches, select a different Scene Number and repeat step C. E) Once all scenes are loaded, click OK to exit the Lighting Scene Setup. Programming To add a Lighting Scene command to an event, select "Lighting Scene" as a then action. Choose the desired scene name in the Lighting Scene list then click OK. This will add a "Lighting Scene: [name]" line to the then section of the event. Download the schedule. - Offhook Detect: Some mechanical ringers produce enough back EMF that the offhook detect circuit indicates a false offhook signal during the quiet period of a ring cycle. The qualification for the offhook condition during a ring cycle has been increased to provide more immunity to this condition. - X-10 Preset Commands: An X-10 Preset value of 0 % will now set the modules state to OFF, a Preset value greater than 0 % will now set the modules state to ON. - Security Offset: The calculated Security Offset would not properly wrap around as the calculated time approached midnight. This caused times using the security option to occasioundly miss being triggered. ---------------------------------------------------------------- VERSION 2.41 KEY FEATURES: - Supports 8 independent VoiceMail boxes (1 general, 7 private). - VoiceMail functions include: play, delete, repeat, skip, back 5 seconds, forward 5 seconds, Caller ID announce. - Each mailbox can store up to 255 incoming messages. - Approx. 18 minutes total record time (40 minutes with optional Voice Memory Upgrade). - Supports pager notification with Caller ID - After a message is left, it can dial a pager and enter the CallerID of the caller. - Custom greetings can be selected based on Caller ID, time of day, etc. - Voicemail messages can be played back through any on or off premise phone, dedicated speakers or existing audio components. - Voicemail functions can be controlled by telephone and from the WinEVM VoiceMail Utilities menu. - Calls can be live-transfered to any VoiceMail box. - Any macro can be triggered after a message is left in a VoiceMail box. - VoiceMail parameters (number of rings before answer, greeting selection, etc.) can be changed via schedule. - Custom VoiceMenus can be setup for voice-prompted access to system functions (security, hvac, etc.). - Built-in VOX automatically hangs up after 7 seconds of silence or if dial tone is detected. Refer to the file: VOICEMAI.DOC (MS Word Document) for detailed description and usage. VERSION HISTORY OVERVIEW 2.41b (7 July 1998) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. Incorporated numerous additions and changes, including: - Voice Memory Chip Upgrade: Support for the second Voice Memory Chip (U2) increases the available recording time by approximately 25 minutes. Refer to the Upgrade instructions for details. - Retriggerable Delays: Version 2.41a introduced a problem with retriggerable delays never expiring. This has been fixed in version 2.41b. VERSION HISTORY OVERVIEW 2.41a (16 Jun 1998) IMPORTANT NOTE: For your first download after a Self-Test, it is essential to select ALL download options to properly initialize STARGATE. Incorporated numerous additions and changes, including: - Digital Input latency: The Digitial Inputs under version 2.41 exhibited latency (sluggish response). The sampling frequency has been changed back to pre-2.41 frequencies. - Leviton 6381: Modules set to the 6381 type in the X-10 database have the following new features: 1) Refresh routine sends out pre-set levels instead of ON/OFF 2) MegaController grid shows ON/OFF state (if pre-set to 0%, grid will show as OFF, if pre-set to any value above 0% grid will show as ON. 3) Loading variable with Pre-Set level: If Module is off (actually set off with X-10 OFF command, not pre-set to 0%), the variable is loaded with 0, otherwise it is loaded with 1-32 cooresponding with the preset levels. 4) Setting Pre-Set level with variable: If variable == 0, an X-10 OFF command is sent, otherwise a variable value of 1-32 sends the cooresponding Pre-Set levels. - Message Log: Fixed the problem with the Message log reaching it's capacity and losing some stored messages. VERSION HISTORY OVERVIEW 2.41 (01 Jun 1998) IMPORTANT NOTE: The file REM_ACC.ZIP is a zipped file (REM_ACC.DBF) containing an example of a complete VoiceMail/VoiceMenu system setup. Before unzipping this file to your STARGATE directory, copy your existing REM_ACC.DBF file from your STARGATE directory to a floppy or other directory (or rename the file) so you can access your original telephone setup parameters if necessary. Incorporated numerous additions and changes, including: - VoiceMail/Remote Access: A new dynamic VoiceMail/VoiceMenu system is available. - 16 HVAC Zones: Increased the number of HVAC Zones supported from 8 to 16. - Fast Events: Events triggered by an IR Command received. These events are executed immediatly when triggered regardless of schedule size. Note that there can only be 1 Fast Event for a given trigger. Fast Events are created by selecting the New Event button from the right toolbar, then selecting 'Fast Event' for the Event type. The Fast Event trigger window allows the selection of the trigger. - Caller ID Name Support: Caller ID Names are displayed in the MegaController in real time and saved in the Telephone Log. - TouchTone to user_VAR/TimeLabel SYNC option: The SYNC option eliminates the need for a separate event to look for the IF Condition "TouchTone to user_VAR/TimeLabel complete". Selecting the SYNC option will pause the entire schedule until either: 1) A valid TouchTone entry 2) Invalid TouchTone entry 3) 10 second timeout EXAMPLE THEN Macro: Change Setpoint MACRO BEGIN Voice: ENTER NEW TEMPERAT [Spkr,CO,ICM] TouchTone to user_VAR SYNC (V:Temp Setpoint) load with user_VAR |-If |(V:Temp Setpoint) < 80 |(V:Temp Setpoint) > 60 |Then | (HVAC:Thermo) Change Setpoint to value in user_VAR | Voice:BBBEEP [CO,ICM] | DELAY 0:00:04 | Voice:NEW SET TEMPERAT IS Thermo Setpoint DEGREES [CO,ICM] |Else | Voice:INVALID TEMPERAT [CO,ICM] |- Nest End MACRO END - MegaController HVAC: The interactive "READ" button now shows the current mode and fan setting along with temperature and setpoint. Clicking on the mode or fan radio buttons will change the HVAC zone settings accordingly. - Define THEN Macro Icon on Button Bar: The THEN Macro Button will display the Define THEN Macro window. *** Note the following changes to the Remote Access System*** 1) The Remote Access prompt has been changed to a single User Voice Response. 2) The Remote Access fields have been moved from the Define Telephone window to the Define VoiceMail + Remote Access window. VERSION HISTORY OVERVIEW 2.40d (2 Jan 1998) Incorporated numerous changes, including: - Changed the criteria for logging a local call from 7 digits dialed (the first digit not being * or #), to 7 - 9 digits dialed, to accommodate customers who need to dial "1" followed by 7 digits for local calls. - Touch-Tone out is slightly faster. - Fixed the multiple full screen problem. (If a schedule was set to full screen and you tried to change to another schedule also at full screen, the second window would show up as a blank window.) - Support for the Leviton Repeater with the new extended codes. ***Note that Leviton has made a change to their repeater *** The original #6201 repeater was not repeating the code properly from the source phase to the destination phase(s). Leviton 6381 dimmers on the same phase as the source would operate properly, but the other phases would get an invalid code and not work with the extended codes (pre-sets). If you are going to use the 6381-SAN020 switches with preset support, any repeater purchased before Jan 1998 will not work properly. - Some customers experienced an early timeout when accessing STARGATE remotely. It was determined that various factors including CO voltages and loop lengths affected the time needed to take a line offhook. The time limit for an offhook transition was increased to compensate for the longer times. -Support for RCS "Auto-Send" feature. With Auto-Send is enabled, the RCS thermostat will automatically send a corresponding Preset Dim command anytime there is a change in temperature, set point or mode, even when operated manually at the thermostat display unit. This eliminates the need to poll the thermostat regularly. (Polling frequency can then be set to "0" in the DEFINE -RCS HVAC menu.) To enable the "Auto-Send" feature, open Megacontroller, then right mouse click on Unit code 4 (of the House Code defined for RCS HVAC), select PRESET Level, then click on Preset Level 84%. ***Note: "Auto-Send" feature will be disabled after a power outage. It is recommended that you add an event to your schedule to automatically issue Unit 4 Preset Level 84% when power is restored. *** Example: EVENT: Restore Auto-Send If Power is Restored Then X10: (A-4) PRE-Set Level 84% End VERSION HISTORY OVERVIEW 2.40c (12 Nov 1997) Incorporated numerous changes, including: - Added two new IR Frequency selections for the IRXP2. 20Khz (used with cable boxes) and 85Khz. - Corrected the Define X10 Voice Response field. Previously a P-16 would appear after an edit but clear after exiting the field. - Fixed the problem encountered when downloading while the X10 Initial Device update is occuring. After a download with Initial Device selected, STARGATE will update the states of any X-10 device that is Enabled and has an Initial state of ON or OFF by sending the appropriate command(s). Previously, if during this update period another download was initiated, the last X-10 command that was being sent (before the 2nd download) could possibly get sent many times. VERSION HISTORY OVERVIEW 2.40b (30 Oct 1997) *** RCS Thermostat Users Note *** Make sure to enable all X10 addresses for housecodes used by RCS Thermostats in the DEFINE - X10 database. For example, if a Thermostat is using housecode P, enable P-1 through P-16 in the X10 database. Incorporated numerous changes, including: - Enhanced the X10 Initial Device download and update of the Controller. MegaController now shows an 'X' for those devices that are not enabled. The right-mouse button menu has a direct enable/disable option. - Moved the Define-Voice Output menu item into the Define-X10 screen. - Fixed the problem when recording a User-Defined IVR response from the CO line. After recording, Touch-Tone digits were disabled. - Removed the Rules Check error for nested Events using X10-Sequences. - Touch-Tone out is slightly faster. - Fixed the problem with sending X10 DIM/BRI commands with the send count equal to 1. (This previuosly caused many DIM or BRI commands to be sent.) VERSION HISTORY OVERVIEW 2.40a (1 Oct 1997) - Version 2.40 required a statement in the winevm.ini file to enable the download of Fast Events. This requirement was removed in 2.40a.